The National
Consensus Report on Helicobacter pylori Infection Management (part of
non-eradication treatment) suggested that Hp infection was the most
controllable risk factor for gastric cancer, with a consensus level of 100%. It
can be seen that the diagnosis of Helicobacter pylori is extremely important
for people's life safety and health. Urea breath test (UBT) is the most widely
used in clinical diagnosis of Helicobacter pylori. Because of its rapid,
simple, non-invasive, high sensitivity and high specificity, it has become the
most widely used and most accurate non-invasive test method for the diagnosis
of infection in the world. Among all kinds of urea breath test techniques, 13C-UBT has more than 95% sensitivity and specificity, and is widely used because
it is non-radioactive and has no special restrictions on subjects. 13C-UBT test
has been applied in most physical examination centers and outpatient clinics,
with a large number of applications.
It is of great
significance to ensure the accuracy of the measurement value of the 13C breath
detector. Accurate and reliable measurement results can improve the accuracy of
Helicobacter pylori diagnosis and avoid misdiagnosis and mistreatment. Gain a
better understanding of individual conditions and improve the effectiveness of
patient care; It can improve the treatment effect of patients and reduce the
risk of exacerbation and admission. It can also reduce inappropriate
prescribing and inappropriate referrals. So how to ensure the accuracy and
reliability of the 13C breath detector measurements?
The newly
developed DOB-13C Urea Breath Detector Calibrator of EUCA Technology Co., Ltd. aims at accurate calibration and regular verification of
13C breath detector. To ensure the accuracy and reliability of the measurement
values of the 13C breath detector. DOB-13C Urea Breath Detector Calibrator, the source gas type is DOB gas certified standard material, Urel≤1%, k=2; DOB measurement range is
0~50; Extended uncertainty Urel≤4%, k=2.
Product advantage
- High accuracy of
quantity value: the type of source gas is DOB gas certified standard material,
Urel≤1%, k=2
- Wide measuring
range: DOB measuring range is 0~50
-Strong
reliability: Extended uncertainty Urel≤4%
- Traceability:
Calibration by the Chinese Academy of Metrology
Product value
- Accurate quantity
value: dynamic and stable occurrence, easy to accurately calibrate traceability
- Wide coverage: The
DOB measurement range is 0~50
- High value:
Accurate calibration guarantees the selection and optimization of patient
protocols